Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Trauma (Majadahonda) ; 24(3): 195-199, jul.-sept. 2013. tab, ilus
Artigo em Espanhol | IBECS | ID: ibc-115582

RESUMO

Objetivo: Validar un sistema de medici¨®n fotom¨¦trica de part¨ªculas en aire para realizar los controles de bioseguridad ambiental de quir¨®fanos y otras salas de ambiente controlado en los hospitales. Material y m¨¦todos: Se realizaron un total de 144 mediciones pareadas de aire, 88 en ocho quir¨®fanos con sistemas de ventilaci¨®n convencional y tres niveles de filtraci¨®n y 56 en nueve habitaciones sin instalaciones de ventilaci¨®n. Se midieron part¨ªculas de entre 0,1 a 10 ¦Ìm en mg/m3 por m¨¦todo fotom¨¦trico. Simult¨¢neamente, en cada sala se realiz¨® impacto de aire en placas de Petri con medio de cultivo mediante aparato aspirador de cabezal perforado, obteniendo tras cinco d¨ªas de incubaci¨®n recuento de unidades formadoras de colonias (UFC)/1000L. Finalmente se realiz¨® el c¨¢lculo de los puntos de corte ¨®ptimos para la medici¨®n de part¨ªculas mediante Curvas ROC para discriminar tres niveles de contaminaci¨®n. Resultados: El coeficiente de correlaci¨®n entre las dos mediciones fue 0,779 (p<0,001). Los puntos de corte fueron para 0 UFC. 0,015, para >=10 UFC, 0,037, y para >=100 UFC, 0,053. La sensibilidad para estos puntos fue de 95,83%,100% y 100%, y los ¨ªndices Kappa registraron 0,51, 0,88 y 0,75 respectivamente. Conclusi¨®n: En nuestro estudio la correlaci¨®n entre las medidas es notable; la medici¨®n fotom¨¦trica de part¨ªculas puede ser una alternativa para llevar a cabo alguno de los controles rutinarios de bioseguridad (AU)


Objective: Validate a photometric on-air particle measurement system in order to perform ambient bio-security checks in operating rooms and other clean rooms within hospitals. Material and methods: A total of 144 coupled air samples were performed, 88 in 8 different operating rooms with conventional ventilation systems and 3-level filtering and 56 in 9 different rooms without specific ventilation systems. Particles were measured in size between 0,1 to 10 ¦Ìm with the photometric system in mg/m3. Simultaneously in the rooms are performed the sampling air method with impact on culture media. Incubation period is 5 days and count is performed in colony-forming units (CFU/1000L). Finally, optimal cut-points in particles measure were calculated using ROC curves in order to discriminate the three different contamination levels. Results: Spearma´s correlation coefficient was 0,779 p<0,001. Sensitivity for cut-points in particle counting for the different contamination levels was 95,83% ,100% and 100% respectively, and the corresponding Kappa indexes were 0,51; 0,88 and 0,75. Conclusion: Correlation among measurements is notable. Particle measurement can be a worthy alternative for some of the routine bio-security checks (AU)


Assuntos
Humanos , Masculino , Feminino , Fotometria/métodos , Fotometria , Salas Cirúrgicas/organização & administração , Salas Cirúrgicas/normas , Salas Cirúrgicas , Sistemas de Informação em Salas Cirúrgicas/normas , Contenção de Riscos Biológicos/métodos , Contenção de Riscos Biológicos/prevenção & controle , Contenção de Riscos Biológicos/análise , Contenção de Riscos Biológicos/estatística & dados numéricos , Poluição Ambiental/análise , Poluição Ambiental/prevenção & controle , Infecção Hospitalar/epidemiologia , Infecção Hospitalar/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...